BeamPro compact footprint Laser Beam Profiler

Beam Profiler with thickness less than 15 mm

Femto Easy BeamPro beam profilers are available with the most compact footprint for laser beam measurements in small spaces.

Small pixel size down to 1.45 µm


High Resolution up to 8 Mpx


375 – 1100 nm & UV extension

Compact package

Compact footprint

2 types of housing with thickness less than 15 mm

BeamPro icon logo

Ideal for OEM integration or cluttered optical tables

Leverage the slim design to place the measurement device anywhere.

Other BeamPro models


Technical Specification

Femto Easy’s BeamPro laser beam profiler comes with a user-friendly and powerful software at no additional costs. Compare the technical specifications and discover your favorite model with a compact footprint.

LP6.3µ-BP8.4µ-BP4.2µ-BP6.4µ-BP7.6µ-BP7.4µ-BP5.4
Pixel size (µm)1.452.002.202.202.743.453.75
Spectral range (nm)375 - 1100
190 - 1100 with UV option
Sensor size (mm)
5.6 x 3.17.7 x 4.34.2 x 2.45.7 x 4.36.8 x 5.76.6 x 4.24.8 x 3.7
Sensor formatSMSMMMS
1/3"1/1.8"1/3.7"1/2.5"1/1.8"1/2.3"1/3"
Resolution3864x2176
8.4 Mpx
3840x2160
8.3 Mpx
1920x1080
2.0 Mpx
2592x1944
5.0 Mpx
2472x2064
5.1 Mpx
1920x1200
2.3 Mpx
1280x960
1.2 Mpx
Shutter typeRollingRollingRollingRollingGlobalGlobalGlobal
Min beam diameter
(Φ FWHM, µm)1
7101111141719
Max acquisition
frame rate (fps)2
244515142016054
Exposure time min31 µs380 µs331 µs352 µs316 µs17 µs30 µs
Exposure time max1s
Dynamic (dB)70715858707158
Price■ ■ ■ ■ ■ ■
Sensor typeCMOS
Bit depth12 / 16 (with HDR option)
PC InterfaceUSB 3.1
SynchronizationYes (with the Trigger option)
Dimensions (mm)40x45x1233x29x1033x29x1033x29x1033x29x1033x29x1033x29x10
1 The minimum beam diameters are specified for a precision of measurement better than 1%. Smaller beam diameter can be measured but the error will progressively increase.

2 Depending on the type of calculation, frame rate may vary.

3 Due to rolling shutter, the actual minimum exposure time to properly capture the whole beam will be limited by the laser beam size (in case of single-shot measurement) or by the laser repetition rate. For single-shot measurement : the larger the beam, the longer the required minimum exposure time. Otherwise, the slower the repetition rate, the longer the required minimum exposure time.

Optional Features

Windowless: Removal of the BeamPro sensor window to avoid potential interferences

UV extension: Increases the BeamPro wavelength range to the UV region, down to 190 nm

Additional ND filters:  The default BeamPro configuration includes one ND filter (ND4). Additional filter with different specifications can be ordered

High Dynamic Range: Software mode to increase the dynamic of the BeamPro signal acquisition from 12 to 16 bits. Not compatible with pure single-shot measurement as 2 images are necessary to build one beam profile image

Vacuum compatible versions up to 10-8 mbar: Possibility to place the BeamPro and perform measurements directly inside a UHV vacuum chamber (not available for all models, please contact us for details)

Trigger: Synchronization of the BeamPro detection to an external signal for accurate laser single pulse measurement


Beam profiler software STAR

  • Live extraction of beam properties, even with resolutions larger than 20 Mpx
  • Several parameters and methods supported (ISO calculation included)
  • Enhanced background & hot pixels treatment for optimum dynamic and signal-to-noise ratio
  • Client / Server interface, allowing remote control through network
  • Advanced logging and permanent access to the 10 previous acquisitions
  • Live comparison with up to 10 different reference measurements
  • 1-click installation, completely configurable, export assistant
en_USEnglish